High Availability Monitors Version A.03.02 Release Notes

NOF Indications
DOWNSTREAM_PU_INDICATION
Chapter 61108
Name of the link station associated with the
downstream PU. This is an 8-byte ASCII string,padded
on the right with spaces if the name is shorter than 8
characters.
pu_sscp_sess_active
Specifies whether the PU-SSCP session to the
downstream PU is active. Possible values are:
AP_YES
The session is active.
AP_NO
The session is not active.
dspu_services
Specifies the services provided by the local node to the
downstream PU.
Possible values are:
AP_PU_CONCENTRATION
Downstream LU is served by PU concentration.
AP_DLUR
Downstream LU is served by DLUR.
pu_sscp_stats.rcv_ru_size
Reserved (always set to zero).
pu_sscp_stats.send_ru_size
Reserved (always set to zero).
pu_sscp_stats.max_send_btu_size
Maximum BTU size that can be sent.
pu_sscp_stats.max_rcv_btu_size
Maximum BTU size that can be received.
pu_sscp_stats.max_send_pac_win
Reserved (always set to zero).
pu_sscp_stats.cur_send_pac_win