High Availability Monitors Version A.03.01 Release Notes

Chapter 1 7
High Availability Monitors Version A.03.01 Release Notes
Required Patches and Known Problems
Required Patches and Known Problems
Required Software Patches
The following patches (or their supersedents) are required. You must
install these patches before you install HA Monitors.
PHKL_16751 (HP-UX 10.20) (981023)
Cumulative patch for SCSI/SIG_IGN/SIGCLD/LVM, JFS, PCI.
(Supersedes PHKL_16388, PHKL_16410)
PHKL_13044 (HP-UX 10.20) (981023)
SCSI pass-through driver cumulative patch. Needed if you use the
disk monitor to monitor disks on an NIO bus. For HP-UX s800.
See Software Requirements, below, for directions for configuring
the SCSI pass-thru driver, spt0, into the kernel.
PHSS_17944 (HP-UX 10.20) OR
PHSS_17945 (HP-UX 11.0)
OV EMANANTE14x consolidated patch. This patch upgrades the
SNMP master agent to send events using SNMP traps, and it
includes a Native Agent Adapter (naaagt) that Oracle SNMP
depends on.. After you install this patch, you need to set the
following in the /etc/SnmpAgent.d/snmpd.conf file:
get-community-name: public
If you choose a different community name, you must open each
/etc/opt/resmon/dictionary/mibmond.dict and
/etc/opt/resmon/dictionary/rdbmsmond.dict file. Add this
option to the end of each MONITOR directive:
-c
<community_name>
Refer to the man page for each monitor for more information.
PHSS_17199 (HP-UX 11.0) (990218)
Fibre channel mass storage driver patch. For HP-UX s700 and
s800. (Supersedes PHSS_17108.) Please refer to Software
Requirements, below for more information about fibre channel.
PHSS_16209 (HP-UX 11.0) (980828)