High Availability Monitors Version A.03.01 Release Notes
Chapter 1 7
High Availability Monitors Version A.03.01 Release Notes
Required Patches and Known Problems
Required Patches and Known Problems
Required Software Patches
• The following patches (or their supersedents) are required. You must
install these patches before you install HA Monitors.
— PHKL_16751 (HP-UX 10.20) (981023)
Cumulative patch for SCSI/SIG_IGN/SIGCLD/LVM, JFS, PCI.
(Supersedes PHKL_16388, PHKL_16410)
— PHKL_13044 (HP-UX 10.20) (981023)
SCSI pass-through driver cumulative patch. Needed if you use the
disk monitor to monitor disks on an NIO bus. For HP-UX s800.
See Software Requirements, below, for directions for configuring
the SCSI pass-thru driver, spt0, into the kernel.
— PHSS_17944 (HP-UX 10.20) OR
— PHSS_17945 (HP-UX 11.0)
OV EMANANTE14x consolidated patch. This patch upgrades the
SNMP master agent to send events using SNMP traps, and it
includes a Native Agent Adapter (naaagt) that Oracle SNMP
depends on.. After you install this patch, you need to set the
following in the /etc/SnmpAgent.d/snmpd.conf file:
get-community-name: public
If you choose a different community name, you must open each
/etc/opt/resmon/dictionary/mibmond.dict and
/etc/opt/resmon/dictionary/rdbmsmond.dict file. Add this
option to the end of each MONITOR directive:
-c
<community_name>
Refer to the man page for each monitor for more information.
— PHSS_17199 (HP-UX 11.0) (990218)
Fibre channel mass storage driver patch. For HP-UX s700 and
s800. (Supersedes PHSS_17108.) Please refer to Software
Requirements, below for more information about fibre channel.
— PHSS_16209 (HP-UX 11.0) (980828)