High Availability Monitors Version A.03.00 Release Notes
6 Chapter 1
Required Patches and Known Problems
Required Patches and Known Problems
Required Software Patches
• The following patches are required with HA Monitors and the Event
Monitoring Services. You must install these patches before you install
HA Monitors.
• PHSS_10715
This patch upgrades the SNMP master agent to version 14.x,
which is required if you plan to send events using SNMP traps.
After you install this patch, you need to set the following in the
/etc/SnmpAgent.d/snmpd.conf file:
get-community-name: public
• PHKL_13044 (HP-UX 10.20)
This patch is required for HP-UX, version 10.20, if you use the
disk monitor to monitor disks on an NIO bus. See Software
Requirements, below, for directions for configuring the SCSI
pass-thru driver, spt0, into the kernel.
• PHSS_14652 (HP-UX 11.0)
This patch, or the one that supersedes it, installs the latest fibre
channel driver on HP-UX 11.0. Please refer to Software
Requirements, below for more information about fibre channel.
Known Problems and Workarounds
The following are known problems with the HA Monitors product, or
with Event Monitoring Service:
opcmsg protocol
• What is the problem? The opcmsg protocol for communicating with
IT/Operations is supported for managed nodes running HP-UX 10.20
only. The agent that sends opcmsg messages between IT/Operations
and managed nodes is not yet available on HP-UX 11.00.
• What is the workaround? If you want to use opcmsg notification, you
must do it on a node running HP-UX 10.20.