Compaq ProLiant Cluster HA/F500 Administrator Guide
Setting Up the ProLiant Cluster HA/F500 with Switches
3-16 ProLiant Cluster HA/F500 for MA8000 Administrator Guide
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: d-ch3
Codename: Chargers Part Number: 355220-006 Last Saved On: 7/26/02 2:50 PM
Running the Fibre Channel Fabric Setup Utility
IMPORTANT: Run this utility before any NTFS volumes are created on the storage
subsystem. If NTFS volumes exist, running Fibre Channel Fabric Setup and rebooting may
reassign drive letters. Refer to the storage subsystem documentation for details on drive letter
reassignment.
The Fibre Channel Fabric Setup Utility installs the version of the HSZDISK driver
required for Windows NT Clusters in a switched fabric environment.
To run the Fibre Channel Fabric Setup Utility:
1. Insert the storage subsystem CD-ROM from the HSG80 NT Intel platform kit in
the CD-ROM drive.
2. Select Solution Software for ACS.
3. Click Skip Driver Upgrade.
4. Select Fibre Channel Software Setup.
5. Select one of the Fibre Channel Software setups based on your system
configuration.
6. Follow the instructions on the screen.
7. Restart the system.
8. Repeat steps 1 through 7 on the other servers.