Compaq ProLiant Cluster HA/F500 Administrator Guide
Setting Up the ProLiant Cluster HA/F500 with Hubs
ProLiant Cluster HA/F500 for MA8000 Administrator Guide 2-39
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: c-ch2
Codename: Chargers Part Number: 355220-006 Last Saved On: 7/26/02 2:48 PM
Referenced Procedures
The following three procedures are referenced in this chapter as part of the
configuration setup instructions. Apply these procedures only as indicated by the
instructions and tables in this chapter.
Setting Port Topology and the Arbitrated Loop Physical Address
NOTE: Please note that you are now setting port topology to port 2.
1. From the CLI window, type the following command and press Enter:
set this_controller port_2_al_pa=72
2. Type the following and press Enter:
set this_controller port_2_topology=loop_hard
IMPORTANT: Omit step 3 when setting up a single controller configuration.
3. Type the following and press Enter:
restart other_controller
4. Type the following and press Enter:
restart this_controller
5. Wait two minutes for the controllers to restart.
6. Type the following and press Enter:
show this_controller
NOTE: This command assumes that the maintenance port cable is connected to the top
controller of the pair.
7. Verify the following:
port_2_topology=loop_hard (standby)
port_2_al_pa=72 (72 negotiated)