Compaq ProLiant Cluster HA/F500 Administrator Guide

Setting Up the ProLiant Cluster HA/F500 with Hubs
ProLiant Cluster HA/F500 for MA8000 Administrator Guide 2-35
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: c-ch2
Codename: Chargers Part Number: 355220-006 Last Saved On: 7/26/02 2:48 PM
3. Follow the cluster installation instructions in this chapter to set up the second
cluster, with the important exceptions included in Table 2-8.
Table 2-8: Setting Up the Second Cluster (Single Controller Configuration)
Chapter 2 Section Heading Page Action
Installing the Disk Drives, Storage
Controller, and Program Card
2-4 Omit
Set Controller to No Failover 2-8 Omit
Disabling the Command Console LUN 2-9 Omit
Setting Port Topologies and the
Arbitrated Loop Physical Address
2-39 Follow the instructions on page 2-39 of this
chapter instead of those on page 2-10.
Discovering Devices 2-11 Omit
Running the FC-AL Setup Utility 2-12 In step 7, use 04 for Host A and 08 for Host B.
Verifying Controller Properties 2-13
In Table 2-4, use the following text for
Host Ports:
Host Port 2 Requested Topology:
Loop Hard
Host Port 2 Requested Port Address: 72
Host Port 2 Actual Port Address: 72
Configuring a Storageset 2-16 Use the following text for step 9: Enter the
virtual disk name. Windows NT recognizes
D100 through D107 for the second cluster if
the Large LUN Utility is not installed.
Setting up Dual Storage Controllers 2-26 Omit