Compaq ProLiant Cluster HA/F500 Administrator Guide

Setting Up the ProLiant Cluster HA/F500 with Hubs
2-18 ProLiant Cluster HA/F500 for MA8000 Administrator Guide
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: c-ch2
Codename: Chargers Part Number: 355220-006 Last Saved On: 7/26/02 2:48 PM
14. Type the following command and press Enter:
show connections
NOTE: There should only be one connection, if you have a basic configuration. If not,
delete all connections, reboot the server, and repeat the process.
15. Type the following command and press Enter to rename the single connection to
make it available to the cluster.
NOTE: The XX in !NEWCONXX refers to the connection number. Use a naming
convention that will be easy to understand and remember. For example: NODE1T where
Node1 is the name of the server. T stands for the top storage controller in the storage
subsystem. T assumes that the maintenance cable is plugged in the storage controller
that resides in the uppermost slot of the controller slots.
rename !NEWCONXX NODE1T
16. Type the following command and press Enter:
show connections
17. Verify that the new connection name is properly set.
18. Boot the second server. Log in to the domain when the login screen displays.
19. Go back to the CLI window, type the following command and press Enter:
show connections
20. If the connection for the second server is not present, reboot the second server
and try again.