Compaq ProLiant Cluster HA/F500 Administrator Guide
Setting Up the ProLiant Cluster HA/F500 with Switches
3-24 ProLiant Cluster HA/F500 for MA8000 Administrator Guide
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: d-ch3
Codename: Chargers Part Number: 355220-006 Last Saved On: 7/26/02 2:50 PM
11. Type the following command and press Enter:
set unit name disable_access_path=ALL
NOTE: The ALL access must be removed and set to NONE before adding the connection
names defined earlier.
12. Type the following command and press Enter:
show units full
13. Verify that the access is now set to NONE. If not, repeat the command.
NOTE: Access will now consist of the connection names defined earlier.
14. Type the following command and press Enter:
set unit name Enable_Access_Path=connection name
Example: set d0 Enable_Access_Path=NODE1T
15. Repeat step 14 for the second server connection name:
Example: set d0 Enable_Access_Path=NODE2T
16. Type the following command and press Enter:
show units full
17. Verify that the connection names have been properly set. If not, repeat the
commands.
18. Repeat steps 11 through 16 for each logical unit to be used in the cluster
configuration.
19. Close the CLI window.
20. Reboot the server.