Table 2-1: Continuous Access Restrictions continued
Restriction Comment
Each storage system can have a relationship
with one remote storage system.
HSG controllers might be present on the SAN
but cannot interoperate with HSV controllers.
The HSG and HSV controllers must be in
different management zones.
One snapshot or Snapclone allowed per Vdisk. Can be on either the source or destination.
A Continuous Access EVA management zone is
limited to a specified number of large or small
storage systems, depending on distances.
Refer to the HP StorageWorks Continuous
Access EVA Design Reference Guide for
distance limitations.
Up to 28 B-series switches per fabric Seven hops are allowed; three per site and one
as the intersite link.
Up to 24 M-series switches per fabric Three hops are allowed; one per site and one
as the intersite link.
Qualified operating systems:
• Windows Server 2003, Enterprise Edition
• Windows 2000 Advanced Server
For the supported versions of these operating
systems, refer to
http://h18006.www1.hp.com/products/
storage/software/conaccesseva/index.html.
HP ProLiant Cluster HA/F500 for Enterprise Virtual Array Enhanced DT Supplement Guide 2-3