Compaq ProLiant Cluster HA/F500 Administrator Guide

Setting Up the ProLiant Cluster HA/F500 with Switches
3-14 ProLiant Cluster HA/F500 for MA8000 Administrator Guide
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: d-ch3
Codename: Chargers Part Number: 355220-006 Last Saved On: 7/26/02 2:50 PM
Setting Port Topology
Depending on the configuration, you may need to change the port topology settings.
To set port topology settings:
NOTE: Refer to the HSG80 documentation for more details on changing the port topology
settings.
1. From the CLI window, type the following and press Enter:
set this_controller port_1_topology=fabric
2. Type the following and press Enter:
set this_controller port_2_topology=offline
3. Type the following and press Enter:
show this_controller
4. Verify the following:
port_1_topology=FABRIC (Fabric Up)
port_2_topology=OFFLINE (Offline)
Discovering Devices
To enable the controller to discover the disk drives:
1. From the CLI window, type the following and press Enter:
run config
2. Wait a few minutes for the controller to scan and discover the disk drives.
3. Type the following and press Enter:
show devices
4. Verify that the devices discovered are consistent with the disk drives installed.
The disk drives will be named in the DISK##### format. Refer to the storage
subsystem documentation for the naming conventions for storage subsystem
devices.
5. Close the CLI window.