Compaq ProLiant Cluster HA/F500 Administrator Guide

Setting Up the ProLiant Cluster HA/F500 with Switches
3-12 ProLiant Cluster HA/F500 for MA8000 Administrator Guide
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: d-ch3
Codename: Chargers Part Number: 355220-006 Last Saved On: 7/26/02 2:50 PM
Setting Controller to No Failover
To set the storage controller to no failover:
1. Click Start on the taskbar.
2. Select Programs, Command Console, CLI Window to display the Connection
Selection dialog box.
3. Select Serial and click OK to display the Connect Serial dialog box.
4. Select the COM port (the port to which the storage controller is connected).
5. Select a baud rate of 9600.
6. Click Connect to display the CLI window.
NOTE: You may need to press Enter to initialize communications before entering CLI
commands.
7. Type the following command and press Enter:
show this_controller
8. Verify that the “Not Configured for Dual-redundancy” text is displayed in the
controller properties.
9. If not, type the following command and press Enter:
set nofailover
NOTE: If you are unable to connect with the storage controller, reset the controller by
pressing the flashing Reset LED button on the controller, and retry the connection after
two minutes.