Compaq ProLiant Cluster HA/F500 Administrator Guide

Setting Up the ProLiant Cluster HA/F500 with Hubs
2-4 ProLiant Cluster HA/F500 for MA8000 Administrator Guide
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: c-ch2
Codename: Chargers Part Number: 355220-006 Last Saved On: 7/26/02 2:48 PM
Setting Up the Storage Subsystem
Refer to the documentation that was shipped with the storage subsystem for detailed
installation instructions.
Installing the Disk Drives, Storage Controller, and Program Card
The storage subsystem uses hard drives, storage controllers, and PCMCIA program
cards that must be installed (see Figure 2-1).
IMPORTANT: If you are setting up a basic configuration, verify that only one controller is
installed. If more than one controller is present, remove the additional controllers to facilitate
installation of the HA/F500.
To install a disk drive (1):
1. Insert a disk drive into the shelf guide slots.
2. Slide the disk drive into the shelf and use the attached lever to push it into place.
IMPORTANT: For optimum SCSI bus distribution, install the disk drives along different SCSI
buses.
To install the storage controller (2):
1. Insert the storage controller into the top shelf guide slots.
2. Slide the storage controller into the shelf until the mounting tabs snap into place.