Compaq ProLiant Cluster HA/F500 Administrator Guide
Troubleshooting the ProLiant Cluster HA/F500
6-6 ProLiant Cluster HA/F500 for MA8000 Administrator Guide
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: g-ch6
Codename: Chargers Part Number: 355220-006 Last Saved On: 7/26/02 2:54 PM
Nodes Cannot Connect to the Shared Drives
• Verify that a physical connection exists from the second node to the Fibre
Channel storage hub or switch:
— Verify that the shortwave Gigabit Interface Converters (GBICs) are properly
seated.
— Verify that all Fibre Channel cables are properly connected to their GBICs.
• Verify that the shared drives are assigned the same drive letters on both nodes.
To do so, run Windows Disk Administrator on each node and verify that all
shared drives have been assigned identical drive letters. The drive letter
assignments must be permanent.
• If the second node was powered on before either the Fibre Channel storage hub
or switch or the storage subsystem; shut down the second node, turn it off, then
turn it on. The storage subsystem components must be powered on before the
servers.
Troubleshooting Cluster Group and Cluster Resource
Problems
Cluster group and cluster resource problems are related to Microsoft Cluster
Administrator. For troubleshooting tips on this topic, see the Microsoft Cluster Server
Administrator Guide and Microsoft Cluster Administrator online documentation.