21. Type the following command and press Enter to rename the connection for the
second server.
NOTE: The XX in !NEWCONXX refers to the connection number. Use a naming
convention that will be easy to understand and remember. For example: NODE2T where
Node2 is the name of the server. T stands for the top storage controller in the storage
subsystem. T assumes that the maintenance cable is plugged in the storage controller
that resides in the uppermost slot of the controller slots.
rename !NEWCONXX NODE2T
22. Type the following and press Enter:
show connections
23. Verify that the new connection name is properly set.
Verifying Access
To verify access to a storageset:
1. Be sure that the second server is powered down.
2. Click Start on the Windows taskbar.
3. Select Programs, Command Console, CLI Window.
4. Click CLI Window to display the Connection Selection dialog box.
5. Select Serial and click OK to display the Connect Serial dialog box.
6. Select the COM port (the port to which the storage controller is connected).
7. Select a baud rate of 9600.
8. Click Connect to display the CLI window.
9. Press Enter to initialize communications.
10. Type the following and press Enter:
show units full