Compaq ProLiant Cluster HA/F500 Administrator Guide

Setting Up the ProLiant Cluster HA/F500 with Switches
3-18 ProLiant Cluster HA/F500 for MA8000 Administrator Guide
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: d-ch3
Codename: Chargers Part Number: 355220-006 Last Saved On: 7/26/02 2:50 PM
Verifying Properties
To verify the controller properties:
1. Double-click a controller icon in the Storage window to display Controller
Properties.
2. Click the tabs of the Controller Properties screen to confirm that the values in
Table 3-5 are set.
Table 3-5: Controller Properties for Switches
Tab Name Values
General Allocation class: 0
SCSI version: SCSI-2 or SCSI-3
Host Ports Host Port 1 Requested Topology: Fabric
Host Port 1 Actual Topology: Fabric Up
Host Port 2 Requested Topology: Offline
Host Port 2 Actual Topology: Offline
Cache Cache flush time (seconds): 10
Respond to internal cache battery
condition: selected
Command Console LUN SCSI-2 mode—Confirm that the screen is
grayed out (disabled); if not, return to the
“Disabling Command Console LUN”
section.
SCSI-3 mode—Command Console LUN
will be LUN 0 and cannot be disabled.
Connections Operating System: WINNT
Unit Offset: 0 for Port 1
Battery Confirm that the battery is fully charged.
3. Click OK to close the Controller Properties window.