Compaq ProLiant Cluster HA/F500 Administrator Guide
Setting Up the ProLiant Cluster HA/F500 with Switches
ProLiant Cluster HA/F500 for MA8000 Administrator Guide 3-11
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: d-ch3
Codename: Chargers Part Number: 355220-006 Last Saved On: 7/26/02 2:50 PM
Combining Switch Models in a Cluster Configuration
Different SAN switch models can be combined in a cluster configuration. However,
if you experience difficulty establishing communication between different switch
models, perform the following steps:
1. Disable the SAN switches.
2. On the SAN switches, set the following parameter:
vcencode mode = 1
3. Re-enable the SAN switches.
Installing the StorageWorks Command Console Client
Install the StorageWorks Command Console Client (SWCC) software on the host
designated as the maintenance server.
To install the SWCC Client:
1. Insert the storage subsystem CD-ROM from the HSG80 NT Intel platform kit in
the CD-ROM drive.
2. Select Solution Software for ACS.
3. Click Skip Driver Upgrade.
4. Select StorageWorks Command Console (SWCC).
5. Select CLI, Command Window, HSG80 or Newer.
6. Follow the instructions on the screen.
Configuring the Storage Subsystem for Fibre Channel
The storage subsystem is preconfigured with specific parameters. These parameters
may need to be changed depending on which cluster configuration is chosen. This
section will review the required steps to make these changes.