Compaq ProLiant Cluster HA/F500 Administrator Guide
Setting Up the ProLiant Cluster HA/F500 with Hubs
ProLiant Cluster HA/F500 for MA8000 Administrator Guide 2-37
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: c-ch2
Codename: Chargers Part Number: 355220-006 Last Saved On: 7/26/02 2:48 PM
Setting Up Dual Redundant Controllers (Multibus Failover)
To set up a multiple cluster configuration with dual redundant controllers (multibus
failover), refer to Figure 2-7 for an example of this configuration. Since all four ports
are active, the unit offsets are not assigned automatically and must be configured
manually.
1. Set up the first cluster according to instructions in Chapters 2 and 4.
2. After you set up the first cluster, follow the steps on page 2-10 of this chapter to
set the port topology and the ALPA settings for the storage controllers.
3. Follow the cluster installation instructions in Chapters 2 and 4 to set up the
second cluster, with the important exceptions included in Table 2-10.
Table 2-10: Setting Up the Second Cluster (Multibus Failover Configuration)
Chapters 2 and 4 Section Heading Page Action
Installing the Disk Drives, Storage
Controller, and Program Card
2-4 Omit
Set Controller to No Failover 2-8 Omit
Disabling the Command Console LUN 2-9 Omit
Setting Port Topologies and the
Arbitrated Loop Physical Address
2-39 Follow the instructions on page 2-39 of this
chapter instead of those on page 2-10
Discovering Devices 2-11 Omit
Running the FC-AL Setup Utility 2-12 In step 7, use 04 for Host A and 08 for Host B.
continued