Compaq ProLiant Cluster HA/F500 Administrator Guide

Setting Up the ProLiant Cluster HA/F500 with Hubs
2-34 ProLiant Cluster HA/F500 for MA8000 Administrator Guide
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: c-ch2
Codename: Chargers Part Number: 355220-006 Last Saved On: 7/26/02 2:48 PM
Figure 2-7 shows two enhanced cluster configurations connected to dual storage
controllers in a single storage subsystem. The storage controllers are configured as
active/active (multibus failover).
Cluster 1
Server 1
Hub 1
Hub 2
Hub 3
Port 1 Port 2
Storage Subsystem
Active
Active
Active
Active
Port 1 Port 2
Controller 2
Controller 1
Hub 4
Server 2 Server 1 Server 2
Cluster 2
Figure 2-7: Multiple cluster configuration (multibus
failover)
Setting Up Single Storage Controller Configurations
To set up a multiple cluster configuration with a single storage controller (refer to
Figure 2-6):
1. Set up the first cluster according to instructions starting on page 2-3.
2. After you set up the first cluster, follow the steps on page 2-10 of this chapter to
set the port topology and the ALPA settings for the storage controller.