Compaq ProLiant Cluster HA/F500 Administrator Guide
Setting Up the ProLiant Cluster HA/F500 with Hubs
ProLiant Cluster HA/F500 for MA8000 Administrator Guide 2-17
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: c-ch2
Codename: Chargers Part Number: 355220-006 Last Saved On: 7/26/02 2:48 PM
14. Wait for the virtual disk initialization to complete before proceeding (this may
take some time, depending on the size and RAID level of the virtual disk
created).
15. Close the Storage window.
Setting Up Connections
To set up HBA connections:
NOTE: Perform the following steps on one HBA at a time for an enhanced configuration.
1. Type the following and press Enter:
show connections
NOTE: Each connection must be deleted and reestablished in order to properly configure
the HA/F500. Perform the following step if the connections were previously configured.
2. Type the following and press Enter:
delete connection !NEWCONXX
NOTE: The XX in !NEWCONXX refers to the connection number.
3. Repeat the above CLI command for each connection.
4. Close the CLI window.
5. Reboot the server you are currently working on.
6. Click Start on the Windows taskbar after rebooting.
7. Select Programs, Command Console, CLI Window.
8. Click CLI Window to display the Connection Selection dialog box.
9. Select Serial and click OK to display the Connect Serial dialog box.
10. Select the COM port (the port to which the storage controller is connected).
11. Select a baud rate of 9600.
12. Click Connect to display the CLI window.
13. Press Enter to initialize communications.