To install the PCMCIA program card (3) in the storage controller:
1. Remove the program card cover (4) from the controller PCMCIA slot.
2. Insert the PCMCIA program card (3) into the top controller slot.
3. Replace the program card cover (4) over the controller slot.
1
2
3
4
Figure 2-1: Installing the disk drives, storage controller,
and PCMCIA cards (RA8000 shown)
Installing the Host Bus Adapter
Follow the installation instructions in the server documentation to install the host bus
adapter in the servers. Install one adapter in each server.
For the basic configurations (single host bus adapter, single or dual storage
controllers), only one adapter is installed per server. Chapter 4 discusses the
enhanced configuration (dual host bus adapters, dual storage controllers) in which
a second adapter is installed.
Connect the adapter from each server to the Fibre Channel hub. Connect port 1 (the
left port) of the storage controller to the Fibre Channel hub.