Compaq ProLiant Cluster HA/F500 Administrator Guide
Overview of the ProLiant Cluster HA/F500
ProLiant Cluster HA/F500 for MA8000 Administrator Guide 1-15
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: b-ch1
Codename: Chargers Part Number: 355220-006 Last Saved On: 7/26/02 2:46 PM
Hub and Switch Maximums
ProLiant Cluster HA/F500 configurations can involve either hubs or switches.
Table 1-1 shows the numerical maximums for hub and switch configurations. Hub
cascading is not supported. For cascading switches, refer to the StorageWorks
documentation.
Table 1-1: Hub and Switch Maximums
Configurations Hub
Single Cluster
Configuration
Hub
Multiple Cluster
Configuration
Switch
Single Cluster
Configuration
Switch
Multiple Cluster
Configuration
Storage controller pairs
per host bus adapter
2 2 8 8
Hubs or switches
per storage controller pair
2 2 2 2
Clusters (two servers
each) per storage
controller pair
1 2 1 8
Host bus adapters
per host per storage
controller pair
2 2 2 2
Storage controller pairs 2 2 8 8
Storage Subsystem
Drives
168 168 672 672