Compaq ProLiant Cluster HA/F500 Administrator Guide
Overview of the ProLiant Cluster HA/F500
ProLiant Cluster HA/F500 for MA8000 Administrator Guide 1-11
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: b-ch1
Codename: Chargers Part Number: 355220-006 Last Saved On: 7/26/02 2:46 PM
Enhanced Configuration with Switches
Figure 1-7 is a configuration without any single points of failure. It improves on the
basic configuration shown in Figure 1-6 by adding a second host bus adapter to each
server and a second switch. The combination of second adapter, switch, and
controller form a second independent path to the storage subsystem.
To allow dual paths to the storage, the Secure Path software must be installed on all
servers. With Secure Path, data can flow simultaneously over both host bus adapters
to the storage subsystem, and you can perform static load balancing over the
two paths to help maximize performance.
NOTE: The dashed lines indicate maximum configuration.
Fibre Channel
Storage Switch
Fibre Channel
Storage Switch
Interconnect
LAN
Host Bus
Adapters
Host Bus
Adapters
ProLiant
Server
ProLiant
Server
Port 1 Active
Port 1 Active
Controller A
Controller B
Storage
Subsystem
Controller A
Controller B
Storage
Subsystem
Figure 1-7: Enhanced configuration with switches
A component failure in this cluster will result in a failover to a second component,
and the end user can continue using the cluster. Some typical failures and responses
in the enhanced configuration include:
• A server failure will cause Microsoft cluster software to fail over to the
other node.
• A host bus adapter failure will cause subsequent data requests intended for the
failed adapter to be routed over the remaining good adapter.