Compaq ProLiant Cluster HA/F500 Administrator Guide

Secure Path Installation Procedures
4-10 ProLiant Cluster HA/F500 for MA8000 Administrator Guide
COMPAQ CONFIDENTIAL
Writer: Woody Jernigan File Name: e-ch4
Codename: Chargers Part Number: 355220-006 Last Saved On: 7/26/02 2:52 PM
24. Type the following command and press Enter to rename the second server
connection:
NOTE: The “XX” in “!NEWCONXX” refers to the connection number.
NOTE: Use a naming convention that will be easy to understand and remember. For
example: NODE2B where Node 2 is the server. B stands for the top storage controller in
the storage subsystem. B assumes that the maintenance cable is plugged into the other
controller.
When you have two HBAs, you may want to use a naming convention that is more
detailed to the equipment. For example,
rename !NEWCONXX N1A1P1
N1 is Node 1, A1 is adapter 1, and P1 is port 1 on the controller.
rename !NEWCONXX NODE2B
25. Type the following and press Enter:
show connections
26. Verify that the new connection name is properly set. The new connection names
also need to be added.
27. Type the following and press Enter:
set unit name enable_access_path=connection name
Example: set d0 enable_access_path=NODE1B
28. Repeat the preceding command for the second server connection name:
Example: set d0 Enable_Access_Path=NODE2B
29. Type the following command and press Enter:
show units full
30. Verify that the connection names are properly set. If not, repeat the commands.
31. Repeat steps 27 through 30 for each logical unit to be used in the cluster
configuration.
32. Close the CLI window.
Secure Path is now properly prepared and cabled.