HP Code Advisor

The syntax for determining the invocation of the compile or link command after the cadvise
static analysis is as mentioned below:
$ cadvise -nobuild <compilation path> -w <filename>
The following example shows the usage of -[no]build option.
Example 7-4 Using -nobuild option
$ cadvise -nobuild /opt/ansic/bin/cc -w t1.c
This results in the compile command line /opt/ansic/bin/cc -w t1.c not getting
executed.
-target[=.ext|filename] This option creates an empty file called filename or
<objectfile>.ext in the current directory, which is used as an updated makefile target.
When cadvise is called with the -nobuild option from a makefile, the compiler is not
invoked and hence a .o file is not created. When this happens, the makefile target is not
updated. In the absence of a target update, a second call to make invokes cadvise for all the
targets again, instead of only the ones that have been modified.
NOTE: If filename is not specified, cadvise creates objfile.cadv.
The following example shows the usage of -target[=.ext|filename] option.
Example 7-5 Using -target[=.ext|filename] option
The following command creates the file foo.cadv:
$ cadvise -nobuild -target cc foo.c -o foo.o
The following command creates the file cadv_dir/foo.cad:
$ cadvise -nobuild -target=cadv_dir/foo.cad cc foo.c
-tee You also have the choice of looking at the errors and the diagnostic messages
immediately with the -tee option, or generate a report later from the PDB.
The following example shows the usage of -tee option.
Example 7-6 Using -tee option
$ cadvise -compiler cc -tee +wall -pdb 1.pdb /opt/ansic/bin/cc -w t1.c
+opts <filename> This option reduces the clutter at the command line and provides a
single place to specify the customizations. Comment lines can also be inserted in the +opts
configuration file. You can use this option to read reporting options from the specified
filename.
The following example shows the usage of +opts <filename> option.