R21xx-HP FlexFabric 11900 Fundamentals Configuration Guide

24
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Enter AUX user
interface view.
user-interface aux first-number
[ last-number ]
N/A
3. Set the baud rate.
speed speed-value By default, the baud rate is 9600 bps.
4. Specify the parity
check mode.
parity { even | mark | none | odd |
space }
By default, the parity check mode is
none, and no parity check is performed.
5. Specify the number of
stop bits.
stopbits { 1 | 1.5 | 2 }
The default is 1.
Stop bits indicate the end of a character.
The more the stop bits, the slower the
transmission.
6. Specify the number of
data bits for each
character.
databits { 5 | 6 | 7 | 8 }
The default is 8.
The setting depends on the character
coding type. For example, you can set it
to 7 if standard ASCII characters are to
be sent, and set it to 8 if extended ASCII
characters are to be sent.
7. Define a shortcut key
for starting a terminal
session.
activation-key character
By default, pressing Enter starts the
terminal session.
8. Define a shortcut key
for terminating tasks.
escape-key { character | default }
By default, pressing Ctrl+C terminates a
task.
9. Configure the flow
control mode.
flow-control { hardware | none |
software }
By default, the flow control mode is none.
The switch supports only the none flow
control mode.
10. Specify the terminal
display type.
terminal type { ansi | vt100 }
By default, the terminal display type is
ANSI.
The device supports two terminal display
types: ANSI and VT100. To ensure
correct display on the terminal, set the
display type to VT100 on both the device
and the terminal. If either side uses the
ANSI type, a display problem such as
cursor positioning error might occur
when a command line has more than 80
characters.
11. Set the maximum
number of lines to be
displayed on a screen.
screen-length screen-length
By default, a screen displays 24 lines at
most.
A value of 0 disables pausing between
screens of output.
12. Set the size of the
command history
buffer.
history-command max-size value
By default, the buffer saves 10 history
commands at most.