R211x-HP Flexfabric 11900 TRILL Command Reference

43
Examples
# Set the minimum LSP interval to 500 milliseconds and the maximum number of LSPs transmitted per
time to 10 on port Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] trill timer lsp 500 count 10