R211x-HP Flexfabric 11900 MPLS Command Reference
297
Use the shutdown command when you want to temporally disable VPLS. After a VSI is disabled, all
existing configurations of the VSI keep unchanged, and you can further configure the VSI. After the
configuration, use the undo shutdown command to enable the VSI, which will provide VPLS services
using the new settings.
Examples
# Disable the VSI vpn1.
<Sysname> system-view
[Sysname] vsi vpn1
[Sysname-vsi-vpn1] shutdown
Related commands
display l2vpn vsi
signaling-protocol
Use signaling-protocol to specify a signaling protocol used to establish a PW to the remote PE
discovered by BGP and enter specified signaling view.
Use undo signaling-protocol to remove the signaling protocol configuration.
Syntax
signaling-protocol { bgp | ldp }
undo signaling-protocol
Default
No signaling protocol is specified.
Views
Auto-discovery VSI view
Predefined user roles
network-admin
mdc-admin
Parameters
bgp: Specifies the signaling protocol as BGP and enters auto-discovery VSI BGP signaling view.
ldp: Specifies the signaling protocol as LDP and enters auto-discovery VSI LDP signaling view.
Usage guidelines
You can specify only one signaling protocol in the same auto-discovery VSI BGP or LDP signaling view.
You are not allowed to execute this command multiple times to specify different signaling protocols.
Examples
# Use LDP (FEC 129) to establish a PW to a remote PE discovered by BGP and enter auto-discovery VSI
LDP signaling view.
<Sysname> system-view
[Sysname] vsi aaa
[Sysname-vsi-aaa] auto-discovery bgp
[Sysname-vsi-aaa-auto] signaling-protocol ldp
[Sysname-vsi-aaa-auto-ldp]