R211x-HP Flexfabric 11900 MPLS Command Reference
105
undo hello lost
Default
The maximum number of consecutive lost or erroneous hellos is 4.
Views
RSVP view
Predefined user roles
network-admin
mdc-admin
Parameters
times: Specifies the maximum number of consecutive lost or erroneous hellos, in the range of 3 to 10.
Usage guidelines
When the number of consecutive lost hellos or erroneous hellos received from a neighbor reaches the
maximum value specified by this command, the device regards the neighbor failed. If RSVP GR is
enabled, the local device acts as a GR helper to help the neighbor to perform GR.
If the maximum number is too big, neighbor failures cannot be promptly detected. If the maximum
number is too small, an operating neighbor might be regarded failed.
This command can take effect only after the RSVP hello extension function has been enabled by using the
rsvp hello enable command.
Examples
# Set the maximum number of consecutive lost or erroneous hellos to 6.
<Sysname> system-view
[Sysname] rsvp
[Sysname-rsvp] hello lost 6
Related commands
• hello interval
• rsvp hello enable
keep-multiplier
Use keep-multiplier to configure the PSB and RSB timeout multiplier.
Use undo keep-multiplier to restore the default.
Syntax
keep-multiplier number
undo keep-multiplier
Default
The PSB and RSB timeout multiplier is 3.
Views
RSVP view