R211x-HP Flexfabric 11900 EVB Configuration Guide

7
Ste
p
Command
Remarks
3. (Optional.) Configure the
expected bandwidth of the
S-channel interface.
bandwidth bandwidth-value
By default, the expected
bandwidth of an S-channel
interface is the default maximum
bandwidth of the physical port to
which the S-channel interface
belongs.
4. (Optional.) Restore the default
settings for the S-channel
interface.
default N/A
5. (Optional.) Configure a
description for the S-channel
interface.
description text
The default description information
is "interface name Interface."
6. Bring up the S-channel
interface.
undo shutdown
By default, the S-channel interface
is up.
To configure an S-channel aggregate interface:
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Enter S-channel aggregate
interface view.
interface schannel-aggregation
interface-number:channel-id
N/A
3. Configure a description for
the S-channel aggregate
interface.
description text
The default description information
is "interface name Interface."
4. Bring up the S-channel
aggregate interface.
undo shutdown
By default, the S-channel aggregate
interface is up.
Configuring the RR mode for an S-channel
EVB TLVs exchanged through LLDP allow an EVB station and EVB bridge to negotiate the use of reflective
relay. When the EVB station requests the use of the RR mode and the EVB bridge supports the RR mode,
the bridge automatically enables the RR mode for the S-channel and saves the configuration in the
configuration file on the bridge. You can also manually enable the RR mode for an S-channel by
performing this task.
To configure the RR mode for an S-channel:
Ste
p
Command
Remarks
1. Enter system view.
system-view
N/A
2. Enter S-channel interface
view or S-channel aggregate
interface view.
interface { s-channel |
schannel-aggregation }
interface-number:channel-id
N/A
3. Enable the RR mode for the
S-channel.
evb reflective-relay
By default, the RR mode is
disabled for an S-channel.