HP Software File Migration Agent Installation and Administration Guide (September 2009)

Error Codes and Messages | 163
0x0004000A Wrong number of
bytes written
Error: An Archive Storage
System write request returned
the wrong number of bytes
written confirmation. This
error is produced by the
FmaFileUtil application if it
tries to write data and the
return confirmation does not
match the request.
Contact HP Support.
0x0004000B Data is corrupt Error: An Archive Storage
System write or read request
did not pass validation checks.
The data may be corrupt. This
error is produced by the
FmaFileUtil application if it
tries to write or read data and
the operation validation did not
pass.
Contact HP Support.
0x00050002 Metadata was not
found
Error: There is no FMA
metadata attached to the file.
This occurs during recall and
other metadata operations
where an unmigrated file may
be selected.
The file must be migrated
before it contains FMA
metadata.
0x00050003 Version of HSM
metadata is not
supported.
Error: FMA automatically
upgrades the metadata from
older versions to the current
version. In rare cases, the old
version can be too old to
support. This becomes an issue
if legacy stub files are restored
from a backup set or imported
into a current managed
volume.
Stub files with unsupported
metadata cannot be recalled.
Metadata can be deleted from
managed online files. Most
legacy metadata is supported.
Contact HP Support.
0x00050004 Outdated HSM
metadata format
was detected.
Conversion is
required.
Error: Outdated FMA
metadata format was detected
and the current operation
cannot be completed. The
attached metadata must be
updated to the current version.
This error occurs during
typical file management
operations like recall and
migrate.
This error is typically reported
using code 0x00010010 (File
is outdated). See that code for
more information.
Error Code Error Text Description Recommended Action