FibrChanl-02 (fclp) B.11.31.1204 Fibre Channel Mass Storage Driver for HP-UX 11i v3 Release Notes
Table 17 Table of Driver Versions (continued)
Release DateDriver VersionRelease Name
March 2012B.11.31.1203Application Release 1203
April 2012B.11.31.1204Web Release 1204
Hardware Requirements
This version of the FibrChanl-02 (fclp) Fibre Channel Mass Storage Driver for HP-UX 11i v3 runs
on HP Integrity servers with the HP-UX 11i v3 (11.31) operating system. It supports Fibre Channel
hardware products such as:
• AH403A PCIe Dual Port 8Gb Fibre Channel Adapter
• AH402A PCIe Single Port 8Gb Fibre Channel Adapter
• 456972-B21 Dual Port PCIe Emulex 8 Gb Mezzanine Fibre Channel Adapter
• AD355A PCIe Dual Port 4Gb Fibre Channel Adapter
• AD299A PCIe Single Port 4Gb Fibre Channel Adapter
• AD221A HP PCIe Single Port 4Gb Fibre Channel and Single Port 1000 BT Adapter
• AD222A HP PCIe Dual Port 4Gb Fibre Channel and Dual Port 1000BT Adapter
• AD393A HP PCIe Dual Port 4Gb Fibre Channel and Dual Port 1000SX Adapter
• 403621-B21 Emulex LPe1105–HP 4Gb Fibre Channel Adapter for HP c-Class BladeSystem
• AT094A PCIe Fibre Channel 2-port 8Gb FC/2-port 1/10GBE Combo Adapter
NOTE: Please note these slot limitations on rx3600 and rx6600 servers:
• Slots 5 and 6 are the recommended slots for AD221A, AD222A, and AD393A adapters.
• Slots 3 and 4 are also supported for AD221A, AD222A, and AD393A adapters, but with
these restrictions:
I/O performance of the card may be limited.
Online Replacement is not supported.
Emulex 4Gb Fibre Channel Mezzanine (403621-B21) on HP Integrity blade servers
The Emulex LPe1105-HP 4Gb Fibre Channel Mezzanine Card for HP c-Class BladeSystem (Product
Number 403621-B21) has been shipping on HP Proliant c-Class blades for some time. The cards
have been modified to be compatible with HP Integrity c-Class blades, yet they maintain their
compatibility with Proliant c-Class blades.
The new card versions are sold using the same product number as the previous versions; that is,
403621-B21, but with a new Engineering Date Code to identify the new cards as being compatible
with HP Integrity BladeSystems.
It is not possible to update previous recipes/versions of the Mezzanine card to be compatible with
the HP Integrity blades.
Identification
These are the ways to identify the versions of the cards that are compatible with Integrity c-Class
blades.
EDC change
Newer cards are built with an Engineering Date Code that marks the changes required for Integrity
— Integrity-supported versions have an EDC of B-4813 or later.
Compatibility and installation requirements 11