Fabric OS Message Reference v7.0.0 (53-1002149-01, April 2011)
748 Fabric OS Message Reference
53-1002149-01
AN-1006
119
Severity INFO
AN-1006
Message AUDIT, <timestamp>, [AN-1006], INFO, FABRIC, <event-initiator-details>,
<event-location>, , Bottleneck detection configuration is successfully changed.
Probable Cause Indicates that the bottleneck detection configuration was changed by a user.
Recommended
Action
No action is required.
Severity INFO
AN-1010
Message AUDIT, <timestamp>, [AN-1010], WARNING, FABRIC, <event-initiator-details>,
<event-location>, , Severe latency bottleneck detected at Slot <slot number> port
<port number within slot number>.
Probable Cause Indicates a credit loss.
Recommended
Action
Contact your vendor's customer support for assistance.
Severity WARNING
AN-1011
Message AUDIT, <timestamp>, [AN-1011], WARNING, FABRIC, <event-initiator-details>,
<event-location>, , Could not distinguish between primary and dependent severe
latency bottleneck on slot <slot number> port <port number within slot number>
because port mirroring is enabled on this port.
Probable Cause Indicates that the port mirroring uses the required resources to distinguish between primary and
dependent severe latency bottleneck.
Recommended
Action
The port is recovered. No action is required.
Severity WARNING
AN-1012
Message AUDIT, <timestamp>, [AN-1012], WARNING, FABRIC, <event-initiator-details>,
<event-location>, , Credits did not return from other end. Complete loss of
credits on a VC on slot <slot number> port <port number within slot number>.
Probable Cause Indicates a credit loss.