Fabric OS Message Reference v7.0.0 (53-1002149-01, April 2011)

Fabric OS Message Reference 489
53-1002149-01
Chapter
74
MSTP System Messages
MSTP-1001
Message <timestamp>, [MSTP-1001], <sequence-number>,, ERROR, <system-name>, <msg>:<msg>.
Probable Cause Indicates that the system has failed to allocate memory.
Recommended
Action
Check the memory usage on the switch using the memShow command.
Restart or power cycle the switch.
Severity ERROR
MSTP-1002
Message <timestamp>, [MSTP-1002], <sequence-number>,, ERROR, <system-name>, <msg>:<msg>.
Probable Cause Indicates that the system has failed to initialize.
Recommended
Action
Restart or power cycle the switch.
Severity ERROR
MSTP-1003
Message <timestamp>, [MSTP-1003], <sequence-number>,, ERROR, <system-name>, <msg>:<msg>.
Probable Cause Indicates a socket connection or socket transferring or receiving error.
Recommended
Action
If this is a bladed switch, execute the haFailover command. If the problem persists or if this is a
nonbladed switch, download a new firmware version using the firmwareDownload command. Refer
to the Fabric OS Command Reference Manual for more information on this command.
Severity ERROR
MSTP-2001
Message <timestamp>, [MSTP-2001], <sequence-number>,, INFO, <system-name>, <msg>
Probable Cause Indicates that the MSTP bridge mode has changed.