Fabric OS Message Reference v7.0.0 (53-1002149-01, April 2011)

Fabric OS Message Reference 187
53-1002149-01
EM-1070
25
EM-1070
Message <timestamp>, [EM-1070], <sequence-number>,, INFO, <system-name>, Slot <FRU slot
number> is being powered on.
Probable Cause Indicates a blade is being intentionally powered on.
Recommended
Action
No action is required.
Severity INFO
EM-1071
Message <timestamp>, [EM-1071], <sequence-number>, FFDC, CRITICAL, <system-name>, Unit in
<Slot number> with ID <FRU Id> is faulted, it is incompatible with the following
blade id(s): <blade incompatibility list>.
Probable Cause Indicates that a blade inserted in the specified slot is not compatible with another blade in the
system.
Recommended
Action
Determine which blade is essential to your configuration and remove blades that are incompatible
to it.
Severity CRITICAL
EM-2003
Message <timestamp>, [EM-2003], <sequence-number>,, ERROR, <system-name>, <Slot Id or
Switch for pizza boxes> has failed the POST tests. FRU is being faulted.
Probable Cause Indicates that a field-replaceable unit (FRU) has failed the Power-On Self-Test. Refer to the
/tmp/post[1/2].slot#.log file for more information on faults. To view this log file you must be logged
in at the root level. The ID will be Switch for non-bladed systems.
Recommended
Action
On bladed systems, try reseating the specified FRU.
On nonbladed switches, reboot or power cycle the switch.
If the problem persists:
Run the systemverification command to verify that the switch does not have hardware
problems. To run this command root access is required. Refer to theFabric OS Reference
Manual for more information on this command.
On bladed systems, replace the specified FRU; otherwise replace the switch.
Severity ERROR