Fabric OS Message Reference v7.0.0 (53-1002149-01, April 2011)

180 Fabric OS Message Reference
53-1002149-01
EM-1037
25
EM-1037
Message <timestamp>, [EM-1037], <sequence-number>,, INFO, <system-name>, <FRU Id> is no
longer faulted.
Probable Cause Indicates that the specified power supply has been marked as no longer being faulty, probably
because its AC power supply has been turned on.
Recommended
Action
No action is required.
Severity INFO
EM-1042
Message <timestamp>, [EM-1042], <sequence-number>,, WARNING, <system-name>, Important FRU
header data for <FRU Id> is not valid).
Probable Cause Indicates that the specified field-replaceable unit (FRU) has an incorrect number of sensors in its
FRU header-derived information. This could mean that the FRU header was corrupted or read
incorrectly or corrupted in the object database, which contains information about all FRUs.
Recommended
Action
Try reseating the FRU. If the message persists, replace the FRU.
Severity WARNING
EM-1043
Message <timestamp>, [EM-1043], <sequence-number>,, WARNING, <system-name>, Can't power
<FRU Id> <state (on or off)>.
Probable Cause Indicates that the specified field-replaceable unit (FRU) cannot be powered on or off.
Recommended
Action
The specified FRU is not responding to commands and should be replaced.
Severity WARNING
EM-1044
Message <timestamp>, [EM-1044], <sequence-number>,, WARNING, <system-name>, Can't power
on <FRU Id>, its logical switch is shut down
Probable Cause Indicates that the specified field-replaceable unit (FRU) cannot be powered on because the
associated logical switch is shut down.
Recommended
Action
Run the switchStart command on the associated logical switch.