Using the Event Monitoring Service (November 1999)

Chapter 3 41
Defining a Monitoring Request
Selecting Protocols for Sending Events
Selecting Protocols for Sending Events
Through the Notify via area specify the protocol you want the monitor
to use to send events. The options are described in the following sections.
opcmsg (ITO) Option
This option sends messages to ITO applications via the opcmsg daemon.
For this option to display, IT Operation Managed Node Software 3.x or
4.x must be installed on the resource server running HP-UX version
10.20. This option is not currently available on systems running HP-UX
version 11.0.
The ITO message severity options are:
Map from value (this is not available on all monitors)
Critical
Major
Minor
Warning
Normal
A specified severity other than Normal is returned under the following
conditions:
When value is . . . If this notification option is set, a non-normal
severity occurs when the value changes from FALSE to TRUE.
For example if a disk is being monitored, you want notification when
the disk is down. The When value is condition is FALSE while the
disk is up and running correctly. The condition becomes TRUE,
meaning action needs to be taken, when the disk is down or not
operating correctly.
When value changes If this notification option is set, a non-normal
severity occurs when the current value does not match the previous
value
Certain monitors can map directly to OPC severity levels. This is not
available with all monitors. Select Map from value option from the list
in the Severity area.