9. The monitor checks the resource as specified in the monitor request.
It passes back to the EMS API whether the request is accepted or
rejected.
10. The EMS API provides the interface between the monitor and the
target.
11. The monitor begins collecting data as specified in the monitoring
request.
12. The EMS API interprets the information received from the monitor,
determines if an event occurred, and forwards the notification to the
target applications. The method of informing the target application
of a critical resource value can vary for different target applications.
In the case of ServiceGuard, the client application and the target
application are the same and reside on the same system.