Event Monitoring Service version A.04.20.11.05, A.04.20.23.06, and A.04.20.31.05 Release Notes (March 2010)

Known Problems and Workarounds
The following are the known problems and workarounds:
JAGaf19567 - EMS does not handle registering of persistent requests during boot time
correctly. This results in certain requests getting lost. Persistence files are set to zero if a user
tries to register the persistent requests during the boot phase.
This problem is resolved for emsgui and emscli client. However, this problem will continue
to exist for other clients.
JAGag19389 - WBEM supports the feature of specifying the severity of an event. The severity
level can be critical, major, minor, warning, information, normal, and so on. However, when
emsgui or emscli is used to submit a wbem request, the ems client program does not allow
the user to specify the severity of the notification. By default the program sets the severity
to "Warning".
QXCR1000814468 EMSHAProvider registration fails if the WBEMServices version is earlier
than A.02.05. The registration of EMSHAProvider module fails during the configure phase,
when installing/updating EMS, if the version of WBEMServices product installed on the
system is earlier than A.02.05.
You can follow any of the following workarounds:
Update the WBEMServices product to version A.02.05 or later before updating/installing
EMS.
— If EMS is already installed, user can update the WBEMServices product to version
A.02.05 or later and execute the following command:
# /opt/wbem/bin/cimmof -w -n root/PG_InterOp
/etc/opt/resmon/mof/EMSHAProviderR.mof
For more information on major changes in WBEM version A.02.05, see the HP-UX 11i Version
3 Release Notes: HP 9000 and HP Integrity Servers document on the HP Technical
Documentation website at http://docs.hp.com
Documents available with the Product
The following documents are available with EMS:
Event Monitoring Service Release Notes
Using the Event Monitoring Service user guide
These documents are available on the HP Technical Documentation website at http://
docs.hp.com/en/ha.html.
NOTE: There will be no more updates to the user guides titled Using the Event Monitoring Service
and Using High Availability Monitors. These documents were last updated in June 2007. The Using
the Event Monitoring Service document is available at http://docs.hp.com/en/B7609-90049/
B7609-90049.pdf and the Using High Availability Monitors document is available at http://
docs.hp.com/en/B5736-90074/B5736-90074.pdf.
Software Availability in Native Languages
EMS does not provide native language support. However, separate native language versions of
documentation are available as part of bundle EventMonitoring with the following options:
ABA: American English
ABJ: Japanese
14 Event Monitoring Service Version A.04.20.11.05, A.04.20.23.06, and A.04.20.31.05 Release Notes