Event Monitoring Service Version A.04.20 Release Notes (February 2007)
Event Monitoring Service Version A.04.20 Release Notes
Known Problems and Workarounds
Chapter 18
Known Problems and Workarounds
The known problem and workaround with the Event Monitoring Service version A.04.20
product is provided below.
JAGaf19567 - EMS does not handle registering of persistent requests during boot time
correctly. This results in certain requests getting lost. Persistence files are set to zero if a user
tries to register the persistent requests during the boot phase.
This problem is resolved for emsgui and emscli client. However, this problem will continue to
exist for other clients.
JAGag19389 - WBEM supports the feature of specifying the severity of an event. The
severity level can be critical, major, minor, warning, information, normal, and so on. However,
when emsgui or emscli is used to submit a wbem request, the ems client program does not
allow the user to specify the severity of the notification. By default the program sets the
severity to "Warning".