Event Monitoring Service Version A.04.00.02 Release Notes

Event Monitoring Service Version A.04.00.02 Release Notes
What Is in This Version
Chapter 16
You can write your own monitors, using the EMS Developers’ Kit. The manual and software
can be downloaded free from the Website
http://www.software.hp.com/portal/swdepot/displayInstallInfo.do?productNumber
=B7611BA .
Bastille Interactions
EMS requires SNMP daemon (snmpdm) to query SNMP MIBs and to send SNMP trap
notifications. Selecting an install-time security level while installing the operating system
causes the SNMP daemon (snmpdm) to be shutdown. Therefore, if your system is configured
with any install-time security level, any SNMP MIB-related query or snmp trap notification
will fail. The same behavior will result if snmpdm is disabled manually or by using a tool such
as HP-UX Bastille.
If you want to secure the system using HP-UX Bastille interactively, ensure that the SNMP
daemon service is not disabled for EMS to function properly. Alternatively, after using an
install-time security level, you can manually start the SNMP daemon and related SNMP
subagents mib2agt, hp_unixagt, and trapdestagt.