Event Monitoring Service Version A.03.20.01 Release Notes for HP-UX 11i

Chapter 1 13
Event Monitoring Service Version A.03.20.01 Release Notes for HP-UX 11i
Known Problems and Workarounds
Known Problems and Workarounds
The following are known problems and suggested workarounds with the
EMS:
JAGab77527: EMS client may fail to connect to the
registrar
What is the problem? An EMS client may fail to connect to the EMS
registrar. If this occurs, you may see a message in
/etc/opt/resmon/log/client.log like this one:
-------------------Start Event--------------------
Event 11 occurred at Tue Oct 19 15:53:24.025936 1999
Process ID: 1062 (/etc/opt/resmon/lbin/startmon_client)
Log Level: Error
rm_client_connect: Failed to connect to hprdstts.rose.hp.com,
IP address 15.8.135.200, Port 1712: Invalid argument
-------------------End Event----------------------
-------------------Start Event--------------------
User event occurred at Tue Oct 19 15:53:24.036390 1999
Process ID: 1062 (/etc/opt/resmon/lbin/startmon_client)
Log Level: Error
client connect failed: An error occurred while trying to
connect to a remote system: Invalid argument
-------------------End Event----------------------
What is the workaround? Perform the following:
1. Ensure the inetd is listening on port 1712. To do this, you can
execute the following command. The desired output line is listed here:
netstat -an | grep 1712
tcp 0 0 *.1712 *.* LISTEN
If inetd is not listening on port 1712, be sure the following entry is in
/etc/inetd.conf: