Event Monitoring Service Version A.03.20 Release Notes

16 Chapter1
Event Monitoring Service Version A.03.20 Release Notes
Known Problems and Workarounds
To change the Enforce Dependency Analysis Errors through the
swinstall GUI, follow the steps below:
1. Cancel out of the Analysis.
2. From the Software menu, select Options, then Change. Click OK.
3. Scroll to the box for Enforce Dependency Analysis Errors in
Agent and click to remove the check mark. Click OK.
4. From the Action menu, select Install.
The Status returns:
Ready with Errors. Products scheduled: less than the full
set. Excluded: older version of EMS
5. Click OK.
Install begins.
You will then see error messages similar to the following during the
execution phase:
Summary of Analysis Phase:
ERROR Skipped (in analysis)
EMS-Config.EMS-GUI, r=A.03.20
ERROR Skipped (in analysis)
EMS-Core.EMS-ORE, r=A.03.20
ERROR 2 of 5 filesets had Errors.
3 of 5 filesets had no Errors or Warnings:
ERROR The Execution Phase had errors. See
the above output for details.
NOTE Do not use the -x enforce_dependencies=false option under normal
circumstances. Since the option applies to all filesets with this analysis
error, it would potentially prevent other required filesets from being
installed.
For more information about installation procedures and related issues,