HP StorageWorks 4000/6000/8000 Enterprise Virtual Array Updating Product Software Guide XCS 5.031 (5697-5541, December 2005)
Recommendatio
ns
Before a drive firmware upgrade, back up all of your data.
CAUTION:
• Ifthecodeload
is interrupted by power failure, reboot, or drive removals and additions, data can
be lost.
• Do not power off any components or perform controller resynchs or reboots during an upgrade.
• Do not perform
HP Continuous Access EVA copy/merge activities across sites, site failovers, cloning,
or grouping o
r ungrouping of disks during an upgrade.
Before a drive firmwa re upgrade, back up all of your data. If upgrading destination drives on a system
with HP Continuous Access EVA installed:
• Suspend the intersite link and upgrade all drives on the destination array using the Emergency
quick load procedure.
• Resume the intersite link and allow the merge to complete.
• Perform site failover.
• Suspend the intersite link again and upgrade all drives on the new destination array using the
Emergency quick load procedure.
• Resume the intersite link and allow the merge to complete.
• Perform site failback.
At the beginning of a drive firmware upgrade, a calculation i s performed to determine whether eno ugh
space is ava ilable. If space is exceeded during an upgrade, an event (0x0B01B515) is logged and
the upgrade is suspended until more storage is ad ded to the array.
Table 11 Upgrade events
Event
Indicates
0x0B020004
The drive image is loaded into memory in preparation for c ode
load.
0x0B030004
The drive image is removed from memory.
0x0B040004
Thedriveupgradehasstarted.
0x0B050004
Thedriveupgradehascompleted.
Emergency quick load
Estimated time to complete: 15 - 30 minutes
Upgrade the drive firmware after you upgrade the system software.
CAUTION:
Back up all of your data. If the code load is interrupted by power failure, reboot, or drive removals and
additions, data can be lost.
To upgrade the drive firmware, perform the steps in Upgrading sy stem software.Reviewthetextthat
appears in HP Command View EVA to confirm that you use the correct load method.
After you upg rade the drive firmware, wait five minutes. Using the Controller Event Log in HP Command
View EV A, verify that the drive firmware was successfully upgraded.
42
Upgrading the Enterprise Virtual Array