HP StorageWorks 4000/6000/8000 Enterprise Virtual Array Updating Product Software Guide XCS 5.031 (5697-5541, December 2005)

CAUTION:
In an HP Continuous Access EVA environment, do not begin the upgrade until the following
conditions are met. If you attempt to upgrade the controllers before the following conditions
are met, controller operation will fail.
Ensure that no DR group is logging, merging, leveling, or copying. Furthermore, none
of the DR gr oups can be in a failsafe locked state.
1.
Click the DR group icon in the Navigation pane.
2.
Check the Log state in the DR Group Properties page.
3.
If necessary, stop all copying in HP Continuous Access EVA before you load code.
Ensure the connection between the storage systems is not compromised or failed.
1.
Click the Data Replication folder in the Navigation pane.
2.
Check the Connection State in the Data Replication Folder Properties page.
All EVA storage systems must b e running normally with fully functional controller pairs.
After upgrading the rst controller pa ir (for example, the sourc e controller pair), wait
at least three minutes before upgrading the second controller pair. Make sure the
preceding conditions are met on the second controller pair.
6. Click Code load.
Aconrmation message opens.
Figure 23 First code load conrmation message
7. Click OK.
TheCodeLoadStorageSystem-Page1opens.
Figure 24 Code Load Storage System-Page 1
8. Insert the installation CD-ROM into the computer from which you are browsing.
9. Click Browse and select the le containing version XCS 5.031 of the storage system software from
the installation CD-ROM.
EVA 8000 select either the \\HSV210\5031\210_5031.SSS
or \\HSV210\LAT-
EST\HSV210.SSS le (the les are identical).
38
Upgrading the Enterprise Virtual Array