HP StorageWorks 4000/6000/8000 Enterprise Virtual Array Updating Product Software Guide XCS 5.031 (5697-5541, December 2005)
Figure 22 Initialized Storag e System Properties pag e
3. Check the status of all hardware components in the storage system. Clear all of the hardware errors
before proceeding to the next step.
CAUTION:
If you do not clear all of the hardware errors before you load the new system software, you
risk losing all hardware-related error reports after you load the new system software.
4. Optional.Ifyouwanttoperformanoffline upgrade, stop all host I/Os to the storage system you
are upgrading. After you complete the storage system software upgrade, you can resume host
I/Os to the storage system.
5. Disable the failsafe mode on all DR groups.
updating product software guide XCS 5.031
37