HP EVA Storage Replication Adapter Software for VMware vCenter SRM Administrator Guide

Description/corrective actionGUI error message
The address or login credentials to the management host may
be incorrect, preventing the adapter from connecting.
Initialization of CV Client failed using IP ad-
dress <management host address>.
Connection to the HP P6000 Command View Software host
could not be initialized.
Initialization of the Element Manager object
failed.
A test failover stop operation was called, but no test snapshots
from the test failover stop operation exists.
No test snapshots found.
During a test failover operation, the presentation of a snapshot
to a ESX host failed due to an internal error on the
P6000/EVA.
Presentation of the vdisk <LUN ID> to the host
<host name> has failed.
During test failover start or stop, a test SRM snapshot has
been detected on the array. Unexpected snapshot found must
be deleted before continuing operation
Previously created SRM snapshot found.
The array being requested by SRM is actively managed by
a different HP P6000 Command View Software host.
Storage Array <EVA ID> not found on current
management host.
During test failover stop, a test SRM snapshot has been de-
leted.
Successfully deleted <SRM test snapshot
name>.
All replicated LUNs specified by SRM are already in a failed
over state, or do not belong to a DR Group.
There are no Data Replication Groups to fail-
over.
A LUN ID input from SRM does not belong to any known DR
Group.
VDisk <LUN ID> is not a member of a known
Data Replication Group.
Ensure arrays are functional and that ConsitencyGroup
is available.
Could not retrieve information about consist-
ency group ConsitencyGroup.
Ensure arrays are functional and that DeviceName is avail-
able.
Could not retrieve information about device
DeviceName.
Consistency group ConsitencyGroup is already source on
array StorageName.
Consistency group ConsitencyGroup is
already in source mode.
An error occurred while attempting to failover consistency
group. Check storage system for more information.
Failover of consistency group was unsuccessful.
The address or login credentials to the management host may
be incorrect, preventing the adapter from connecting. Ensure
adapter login credentials are set correctly.
Connection to storage management services
failed at address CoreServiceAddress.
Operation expected to find snapshots of the device Device-
Name, but none were found.
No snapshots found.
Ensure ESX server EsxHostName has been zoned and con-
figured correctly with storage array StorageName and that
devices can be presented to the host.
Presentation of the device DeviceName to the
ESX server EsxHostName failed.
The array being requested by SRM may be actively managed
by a different array manager or might not be configured with
the current array manager.
Storage Array StorageName not found on
current management host.
All replicated LUNs specified by Site Recovery Manager are
already in a failed over state, or are not being replicated.
There are no consistency groups to failover.
Troubleshooting HP P6000 EVA SRA Software version 5.038