HP StorageWorks Windows connectivity 4.0C for the 3000/5000 Enterprise Virtual Array Release Notes (5697-6595, March 2007)

Server support
Windows supports the following servers:
AMD® Opteron-
based ProLiant servers
Intel®-based ProLiant X86 and ProLiant Blade servers
Intel-based EM64T ProLiant servers and Blade servers
HP Integrity s
ervers
Operating constraints
You can nd information about operating constraints specictotheEVArmware and HP StorageWorks
Command View EVA in their respective release notes.
SAN boot procedures
Booting from the SAN is suppor ted for Windows 2000 and Windows 2003 for multipath congurations.
SAN boot procedures are available on the HP StorageW orks website:
h
ttp: //h18004.www1.hp.com/products/storageworks/san/documentation.html
Storage System Scripting Utilit y for EVA
The latest version of the Storage System Scripting U tility (SSSU) is available on the following HP website:
h
ttp: //h18006.www1.hp.com/p roducts/storage/software/cmdvieweva/index.html
From this website, click Software and Drivers.
Avoiding problem situations
This section d escribes problems that may arise and their solutions.
Codeload usage
When a maximally congured system is running at maximum load, codeload functionality is n ot effective.
The system may time out before codeload is complete. HP recommends that you always perform VCS
upgrades at an off-peak time.
SSSU
Changing comments on a disk enclosure
Use Command View EVA to change comments on a disk enclosure. If you try to change a disk enclosure
comment using SSSU, the following error message appears:
Error: Invalid Operation
Changin
g the name of a disk enclosure
Changin
g the name of a disk enclosure is not supported with SSSU or Command View EVA. If you tr y to
change
a disk enclosure name using SSSU, the following error m essage appears:
Error: Invalid Operation
10