HP StorageWorks Windows Connectivity 3.0H for the 3000/5000 Enterprise Virtual Array Release Notes (5697-5396, August 2005)
Table 4 Windows Server 2003 x64 operating system specifications
OS version
Cluster support
FCA (HBA)
Adapter
firmware/ Boot
BIOS version
(minimum)
Adapter
driver version
(minimum)
A7387A
LP1050DC
1.90a4/1.70a1
7-1.03a10
A7388A
LP1050
1.90a4/1.70a1
7-1.03a10
A7560A
1.90a4/1.70a1
7-1.03a10
FCA2404
1.90a4/1.70a1
7-1.03a10
FCA2404DC
1.90a4/1.70a1
7-1.03a10
5.2
5.2 SPI
MSCS
FCA2408
1.90a4/1.70a1
7-1.03a10
Switch support
This version supports the Fibre Channel (FC) switches and firmware versions listed in the HP
StorageWorks SAN design reference guide, available at the following web site:
h
ttp://h18000.www1.hp.com/products/storageworks/san/documentation.html
NOTE:
HP recommends that you do not mix switch firmware versions in your SAN. It is considered a best
practice to uniformly upgrade all switches in the SAN.
Multiple-path support
Windows with EVA storage requires the installation of HP StorageWorks Secure Path on each host to
achieve high-availability, multiple-path capability.
Single-path support
Windows 2000 or Windows 2003 32-bit and 64-bit servers require a single Fibre Channel Adapter
(FCA) to support single-path mode.
NOTE:
Single-path mode should not be used in mission-critical environments.
Server support
Windows supports the following servers:
• AMD Opteron-based ProLiant servers
• Intel-based ProLiant X86, and ProLiant Blade servers
• Intel-based EM64T ProLiant servers and Blade servers
• HP Integrity servers
Windows connectivity 3.0H for the 3000/5000 Enterprise Virtual Array release notes
9