HP StorageWorks Sun Solaris Connectivity 4.0A for the 3000/5000 Enterprise Virtual Array Release Notes (5697-5462, December 2005)

Storage System Scripting Utility for EVA
The latest version of the Storage System Scripting Utility (SSSU) is available on the following HP web site:
h
ttp://h18006.www1.hp.com/products/storage/software/cmdvieweva/index.html
Avoiding problem situations
The following sections describe problems that may arise and their solutions.
Codeload usage
Online codelo
ad functionality is not supported.
Configuring different storage controllers
HP strongly recommends that you not configure different storage controllers on the same HBA. Use
separate HBAs for different multipath controllers.
pkginstall
Ensure that the latest pkginstall patch is installed to possible kernel corruption. For the latest patch,
see the Sun web site:
s
unsolve.s
un.com
SSSU
Changing comments on a disk enclosure
Use Command View EVA to change comments on a disk enclosure. If you try to change a disk enclosure
comment using SSSU, the following error message appears:
Error: Invalid Operation
Changing the name of a disk enclosure
Changing the name of a disk enclosure is not supported with SSSU or Command View EVA. If you try to
change a disk enclosure name using SSSU, the following error message appears:
Error: Invalid Operation
6