HP StorageWorks Linux Connectivity 3.0H for the 3000/5000 Enterprise Virtual Array Release Notes (5697-5391, August 2005)

Changing the name of a disk enclosure
Changing the name of a disk enclosure is not supported with SSSU or Command View EVA. If you try to
change a disk enclosure name using SSSU, the following error message appears:
Error: Invalid Operation
Host considerations
This section contains information and important reminders about the host servers.
Changing the Proliant BIOS
If you have a Proliant server with more than three H BAs installed, you must change a set ting in the BIOS.
Otherwise, you may not be able to see all attached devices. To change the setting:
1. Press F1 to ac cess the ROM-Based Setup Utility (RBSU) during POST.
This is normally after 5i Disk Array initialization.
2. Select System Options > OS Selection>Linux.
3. Select Advanced Options > MPS Table Mode.
4. Select Auto Set Table.
5. Press ESC twice, and then press F10 to save the configuration.
Host type for Linux
For smooth system operation, set the host type for Linux to Sun Solaris except in a LifeKeeper Cluster.
Probe-luns and Secure Path
A kernel panic occurs when the probe-luns command is issued against FCA2214, FCA2214D C,
and A6826A adapters while Secure Path is loaded. An example of this command is: probe-luns
-l -i qla2300.
Selective Storage Presentation (SSP) on SUSE SLES-7
You must reboot the server after using Selective Storage Presentation (SSP) to grant host access to a LUN.
10